The short answer
Many no-heat calls end at the thermostat, the breaker, the furnace's power switch, a blower door that isn't closed, or a clogged filter — all things you can check safely in a few minutes. If those are fine, note the blinking light on the control board and call a licensed technician. If you smell gas, skip all of this: leave the building and call your gas utility from outside.
On this page · 7 sections
Safety first

Smell gas? Leave the building and call your gas utility from outside.

Don't switch lights or appliances on or off, don't try to relight anything, and don't go back in until the utility or the fire department says it is safe. If a carbon monoxide alarm sounds, or people in the house have headaches, dizziness or nausea that ease when they step outside, get everyone out into fresh air and call 911.

A working CO alarm on every level of a home with a furnace is cheap insurance — test it when you change the clocks. Gas piping, burners, venting and the heat exchanger are always work for a licensed technician.

No heat at all

Nothing happens — no click, no fan, no flame. Before you assume the furnace is dead, check what is asking it to run:

  • Thermostat mode and setpoint. It must be on Heat, with the setpoint a few degrees above the room temperature.
  • Thermostat batteries. A blank or flickering screen is often just dead batteries.
  • The breaker. Look for a tripped furnace breaker in the panel and switch it fully off, then on — once.
  • The furnace power switch. It looks like a light switch on or near the furnace, and it gets bumped off more often than you'd think.
  • The blower door. A door switch keeps the furnace off until the front panel is seated firmly. Press it back into place.
  • The filter. A filter caked with dust can starve the furnace of air and trip its safeties. Replace it if you can't see light through it.
  • The error-code light. Most furnaces have a blinking light on the control board, visible through a small window. Count the blinks and match them to the chart inside the door — and photograph both for the technician.

The furnace lights, then shuts off

The burners come on, run for a few seconds or a few minutes, then go out. That pattern usually points at a safety doing its job, not at the flame itself.

  • Dirty flame sensor. A thin rod in the flame. When it is coated, the furnace can't prove there is a flame and shuts the gas off within seconds. Cleaning it is a routine service job.
  • Limit switch from poor airflow. A clogged filter, closed registers or blocked return grilles let the furnace overheat, and the limit switch shuts the burners off. Replace the filter and open every register.
  • Flue and venting. A blocked flue, intake or exhaust stops the draft and the furnace shuts down to keep combustion gases out of the house. You can look for snow, ice or a nest at the pipes outside; anything inside the venting is for a technician.

Blowing cold air

  • Fan set to On instead of Auto. On runs the blower all the time, so you feel cool air between heating cycles. Set the thermostat fan to Auto.
  • Ignition failure. If the blower runs but the burners never light, the igniter or the gas supply is the usual suspect. If the gas range or water heater is out too, call the gas utility.
  • High-efficiency condensate drain or trap. Furnaces with white PVC pipes make water. If the drain, trap or a condensate pump is blocked — or frozen in an unheated space — the furnace stops heating.
  • Frozen PVC intake or exhaust. In snow and ice, the two white pipes outside can be buried or frosted shut. Gently clear snow and ice from around the openings; don't force anything into the pipes.

Short-cycling: on and off every few minutes

A furnace that starts, runs a few minutes and shuts off again wears its parts and never heats the house evenly. Common causes are a clogged filter tripping the limit switch, a dirty flame sensor, a thermostat in a draft or near a heat source, and a furnace that is too big for the house. Check the filter and the thermostat's spot first; time a few cycles with your phone. If it keeps cycling with a clean filter, a technician should check the safeties.

What's safe for you, and where a technician takes over

  • Safe for an owner:thermostat settings and batteries, the breaker and the furnace power switch, the blower door, the filter, open registers, reading the error-code light, and clearing snow from the outside pipes.
  • Reset the breaker or the power switch once. If the same fault comes back, stop resetting it.
  • For a licensed technician:anything involving gas, the burners or gas valve, the flame sensor and igniter, wiring inside the furnace, the venting, and the heat exchanger.
  • Never bypass a limit or pressure switch to keep the burners lit — they exist to keep fire and combustion gases where they belong.

How HVAC Scout helps before you say yes

  1. Step 1
    Photograph the furnace's data tagHVAC Scout reads the brand, model, serial and age from one photo. The free serial decoder on the age page works for furnaces too.
  2. Step 2
    Run the Guided CheckTap what the furnace is doing and answer a few yes/no questions. The Scout Report ranks the likely causes and says how urgent it is.
  3. Step 3
    Check the after-hours quoteSee the typical repair and replacement range for your area and your unit, so you can tell whether an emergency quote is in range before you approve it.
  4. Step 4
    Keep the recordThe unit, the visit and the cost stay on record for the next cold snap, a warranty claim or a sale.

More help: HVAC troubleshooting by symptom, how old is my furnace? (serial decoder) and repair or replace.

Common questions

Why is my furnace not working at all?

Start with what tells it to run. A thermostat still in Cool or Off, dead thermostat batteries, a setpoint below room temperature, a tripped breaker, the furnace's own power switch turned off, or a blower door that isn't fully closed all leave a good furnace silent. Then check the filter and the blinking light on the control board.

Why does my furnace light and then shut off?

Usually a safety is doing its job. A dirty flame sensor stops proving the flame, a clogged filter or closed registers trip the limit switch, and a blocked flue, intake or exhaust stops the draft. On a high-efficiency furnace, a full condensate trap does the same.

Why is my furnace blowing cold air?

Check the thermostat fan first: On runs the blower all the time, even between heating cycles, so set it to Auto. If the burners never light, it is an ignition problem. On a high-efficiency furnace, a frozen or snow-covered white PVC pipe outside or a blocked condensate drain stops the heat and leaves the blower running.

How many times should I reset my furnace?

Once. If it locks out again after a single reset, stop resetting it and call a licensed technician — repeated resets can hide a venting or gas problem.

Is it an emergency if my furnace stops in winter?

It is urgent when the house is getting dangerously cold, someone at home is vulnerable to cold, or pipes could freeze. It is an emergency right away if you smell gas or a carbon monoxide alarm sounds: leave the building and call from outside.

How old is my furnace?

The build year is usually coded into the serial number on the furnace's data tag, inside the blower door or on the cabinet. The free serial decoder on the How old is my AC? page reads furnaces from the same brands, or photograph the tag in HVAC Scout.

Sources

Free to start

Know the fair price before the after-hours call