The short answer
Most air conditioners, heat pumps and furnaces have their build year coded into the serial number on the data tag. Pick the brand and type the serial below to decode it, or photograph the tag in HVAC Scout and it reads the brand, model, size, refrigerant and age for you — and keeps the record.
On this page · 5 sections

Decode your serial number

How the big brands code the year

  • Carrier, Bryant, Payne, Heil, Tempstar: the first four digits are the week, then the year — 1416… is week 14 of 2016.
  • Trane and American Standard: since 2010 the serial starts with the year, then the week — 1823… is 2018. Older units use a single year digit.
  • Goodman, Amana, Daikin: the first four digits are the year, then the month — 1805… is May 2018.
  • Rheem, Ruud, WeatherKing: a plant letter, then the month and year — W0518… is May 2018.
  • Lennox, Armstrong, Ducane: a two-digit plant code, then the year — 5818C… is 2018.

What the age tells you

Age is the first thing to know before paying for a big repair. A unit past about 10–15 years with an expensive repair usually points toward replacing; a younger unit with a small fix is usually worth repairing. See repair or replace for the full checklist.

Skip the decoding: scan the tag

  1. Step 1
    Photograph the data tagOne photo of the outdoor unit's nameplate.
  2. Step 2
    Get the full recordBrand, model, size, refrigerant and age, with how the age was worked out.
  3. Step 3
    Keep it for laterWarranty dates, service history and a clean PDF to share with a contractor, buyer or tenant.

Common questions

How do I find out how old my AC is?

Find the data tag (nameplate) on the outdoor unit — usually a metal or foil label on the side panel near the service valves. Most manufacturers build the manufacture year into the serial number. Enter the brand and serial number above, or photograph the tag in HVAC Scout and it reads the age for you.

Where is the serial number on an air conditioner?

On the data tag of the outdoor condenser, usually on a side or back panel near where the copper lines and wiring enter. The indoor furnace or air handler has its own tag inside the cabinet door. The serial is often labeled S/N, SER or Serial No.

How long does a central AC last?

Many central air conditioners and heat pumps last around 15 years, and ENERGY STAR suggests considering a replacement once a heat pump or AC is more than 10 years old. Coastal air, heavy use and skipped maintenance shorten that; good maintenance stretches it.

My brand isn't listed. How can I tell the age?

Some brands (York and Coleman among them) use letter codes that vary by year and plant. Photograph the data tag in HVAC Scout: it reads the serial, model series and refrigerant together and gives a year range with the reason it was reached.

Does the refrigerant tell me the age?

Roughly. Units charged with R-22 were generally built before 2010, R-410A units mostly from about 2006 on, and units using the newer A2L refrigerants such as R-454B from 2023 on.