Normal: what a heat pump does in winter
- Defrost cycle. In cold, damp weather frost forms on the outdoor coil, and the heat pump reverses for a few minutes to melt it. The outdoor fan stops, you may hear a whoosh or a click, and steam rises off the unit. Then it goes back to heating.
- Lukewarm supply air. Air from a heat pump feels cooler to your hand than air from a gas furnace, and the cycles run longer. It is still heating the house if the thermostat holds its setting.
- Auxiliary heat in a cold snap. When it is very cold outside, or you raise the setpoint a lot at once, the backup heat helps out. "AUX" on the thermostat during those times is expected.
Auxiliary heat vs. emergency heat
Most heat pumps have backup heat, usually electric heat strips in the indoor unit. Auxiliary heat comes on by itself when the heat pump needs help. Emergency heat (EM HEAT) is a setting you choose: it turns the heat pump off and heats with the backup only. Use it when the outdoor unit has clearly failed or is buried in ice, until a technician can look — backup heat costs noticeably more to run, so don't leave it on all winter.
Not normal: signs of a real problem
- Heavy ice that never clears. A thick block of ice on the coil, ice encasing the whole unit, or ice that is still there after defrost cycles points at a defrost, airflow or refrigerant problem.
- Outdoor unit buried or dripped on. Drifted snow, or ice and water dripping from the roof edge onto the top of the unit, blocks the airflow and can freeze it solid.
- Stuck in cooling. Cold air in heating mode for a long time — not just during a few minutes of defrost — can mean the reversing valve or its control has failed.
- The house can't hold the setpoint. If it keeps losing ground on a mild day, with the backup heat running constantly, something is wrong.
Safe checks for an owner
- Thermostat on Heat (not Cool or Off), setpoint above room temperature, fan on Auto, batteries good.
- Breakers for both the outdoor unit and the indoor unit switched on.
- A clean filter at the indoor unit, and every register and return grille open.
- Clear snow from around and on top of the outdoor unit, leaving a foot or two of space. Brush, don't chip — never hit the coil or the fins to break ice.
- If ice from the roof drips onto the unit, note it for the technician or a roofer; a gutter or a small roof over the unit is the usual fix.
When to stop and call a technician
Call a licensed technician if the ice doesn't clear, the outdoor fan won't spin, the unit hums but doesn't run, a breaker trips again after one reset, or it blows cold air in heating mode. Refrigerant, the reversing valve and wiring are not owner-serviceable. If the heat pump has a gas furnace as backup and you smell gas, leave the building and call your gas utility from outside.
How HVAC Scout helps
- Step 1Photograph the outdoor unit's data tagHVAC Scout reads the brand, model, serial and age from one photo, and keeps the unit on record.
- Step 2Run the Guided CheckTap what it's doing and answer a few yes/no questions. The Scout Report ranks the likely causes and says how urgent it is.
- Step 3Check the quoteSee the typical repair and replacement range for your area and your unit, before you approve a winter repair.
- Step 4Keep the recordWarranty dates, the visit and the cost stay with the unit for next winter.
More help: HVAC troubleshooting by symptom, what equipment you can scan and repair or replace.
Common questions
Why is steam coming off my heat pump in winter?
That is almost always the defrost cycle. In cold, damp weather frost builds on the outdoor coil, so the heat pump briefly reverses to melt it. The outdoor fan stops, you may hear a whoosh, and steam rises for a few minutes. Then it goes back to heating. It is normal.
Why does the air from my heat pump feel lukewarm?
A heat pump delivers a large volume of air that is warm, but cooler than the air from a gas furnace, and it runs longer cycles. Air that feels lukewarm to your hand can still be heating the house. If the house can't hold the thermostat setting, that's worth a closer look.
What does EM HEAT mean on my thermostat?
Emergency heat. It turns the heat pump off and heats with the backup heat only — usually electric heat strips. It is meant for when the heat pump itself has failed, and it costs more to run, so use it only until a technician can look.
Is it normal for my heat pump to be covered in ice?
A light frost that clears with each defrost cycle is normal. A thick block of ice that never clears, ice encasing the whole coil, or ice on the top of the unit is not — turn the system to emergency heat and call a technician.
Why is my heat pump blowing cold air?
Check the thermostat first: it should be on Heat (not Cool), with the fan on Auto. During a defrost cycle the indoor air can briefly feel cool. If it blows cold air for a long time in heating mode, the reversing valve may be stuck in cooling — that needs a technician.
Can HVAC Scout read a heat pump's data tag?
Yes. Heat pumps are on the list of equipment you can scan: photograph the tag on the outdoor unit, and the indoor air handler's tag separately — each is its own record.